New LED tubes should give you steady, instant light. If they flicker, buzz, blink, or refuse to start in an old fluorescent fixture, the tube is usually not the real problem. Most of the time, the cause is a mismatch between the tube and the fixture: a tired ballast, wiring that doesn't match the tube type, the wrong sockets, or a loose connection. The good news is that each cause can be checked, and most can be fixed for good. Here's how to find the culprit, step by step.
The quick answer
If you installed plug-and-play (Type A) tubes, an old or incompatible ballast is the most likely cause. If you installed ballast bypass (Type B) tubes, check the wiring and the sockets first: the ballast must be fully removed, the wiring must match the tube type, and every socket must be solid and the right type. In both cases, also check that each tube is fully seated and rotated, and that there's no dimmer on the circuit.
Start here: which kind of LED tube do you have?
LED tubes for fluorescent fixtures come in two main types, and they flicker for different reasons:
- Plug-and-play (Type A) tubes run on the fixture's existing fluorescent ballast. They only work as well as that ballast does, and only if the ballast is on the tube maker's compatibility list.
- Ballast bypass (Type B) tubes are wired straight to line voltage after the ballast is removed. Orilis double-ended LED T8 tubes are this type: line voltage connects to one end of the tube and neutral to the other.
Not sure which you have? Check the tube label or box, or see our guide to ballast bypass vs plug-and-play LED tubes.
6 common causes of LED tube flicker
- An old, failing, or incompatible ballast. This is the number one cause with plug-and-play tubes. Fluorescent ballasts wear out, and a ballast near the end of its life, or one that isn't compatible with the tube, will often make LEDs flicker, buzz, or not start at all.
- A ballast still in the circuit with bypass tubes. Ballast bypass tubes are made to run without a ballast. If the old ballast was left connected, the tubes may flicker, stay off, or fail early.
- A wiring mismatch. Bypass tubes are wired in different ways. A single-ended tube takes line and neutral at the same end, while a double-ended tube takes line at one end and neutral at the other. A tube installed in a fixture wired for the other style won't work properly. (General background: single-ended vs double-ended LED tubes.)
- The wrong type of socket. Many fluorescent fixtures have shunted sockets, where the two contacts inside the socket are connected together. That matters for bypass wiring, as explained below.
- Worn sockets or a loose connection. Old tombstone sockets get brittle, crack, or lose their grip. A tube that isn't fully seated and rotated a quarter turn until it locks, or a loose wire nut, can cause on-and-off flicker, especially when the fixture is bumped or warms up.
- A dimmer or incompatible control. Putting non-dimmable tubes on a dimmer often causes flicker or buzzing. Some lighted switches and occupancy sensors can also leak a small current that makes LEDs glow faintly or blink when they should be off.
Shunted vs non-shunted sockets, in 30 seconds
A tombstone socket has two contacts that touch the two pins on each end of the tube. In a shunted socket, those two contacts are tied together inside the socket. In a non-shunted socket, each contact is separate.
- Single-ended bypass wiring (general education) puts line and neutral on the two pins at the same end. That requires non-shunted sockets at that end. A shunted socket there would connect line and neutral together.
- Orilis double-ended retrofits use non-shunted sockets, with line on the sockets at one end and neutral at the other end. Each socket gets line or neutral, never both.
If you're not sure what sockets your fixture has, the simplest fix is to replace them with new non-shunted sockets while the fixture is open. The Orilis 4-light retrofit kit includes new non-shunted tombstone sockets.
Step-by-step troubleshooting checklist
Work through these in order. The early steps are quick and solve a lot of flicker on their own.
- Turn the power off at the breaker and confirm it's off with a voltage tester. Don't rely on the wall switch.
- Note the pattern. Is it one tube or the whole fixture? Every time, or only when the fixture warms up or gets bumped? One tube points to that tube's sockets or seating. A whole fixture points to the ballast, wiring, or a control.
- Reseat each tube. Remove it, check the pins for damage, then insert it and rotate it a quarter turn until it locks in both sockets.
- Inspect the sockets. Look for cracks, burn marks, loose mounting, or contacts that no longer grip the pins. Replace any worn socket.
- Confirm the tube type matches the fixture. Plug-and-play tubes need a working, compatible ballast. Bypass tubes need the ballast removed and wiring that matches the tube (for Orilis double-ended tubes: line to one end, neutral to the other, non-shunted sockets).
- Check connections. Look for loose wire nuts or wires that have pulled out of the socket terminals.
- Check the controls. Is there a dimmer, lighted switch, or occupancy sensor on the circuit? Test with a standard on/off switch if you can.
- Swap to narrow it down. Try the flickering tube in another fixture that's wired the same way. If the flicker stays with the fixture, the problem is the fixture, not the tube.
Fixes that last
- Bypass the ballast. If a ballast is causing the flicker, replacing it just resets the clock until the next one fails. The long-term fix is usually to remove the ballast and switch to ballast bypass tubes like Orilis double-ended LED T8 tubes. Our guide on how to rewire T12 or T8 fluorescent fixtures for T8 LEDs walks through the wiring.
- Replace worn sockets. New non-shunted sockets often cure flicker that comes and goes.
- Use a kit with everything in the box. The Orilis 4-light retrofit kit includes the LED tubes, wires, tombstones, and wire nuts. It converts two fluorescent fixtures that hold two 4 ft tubes each, or one fixture that holds four 4 ft tubes. Browse all LED retrofit kits.
- Replace the fixture if the housing is shot. If the fixture is rusted, cracked, or in a damp spot, a new integrated LED fixture may be the better move. Orilis IP65 vapor tight LED fixtures come in 2 ft and 4 ft lengths, in 4500K or 6500K.
- Remove the dimmer. If your tubes aren't rated for dimming, put them on a standard on/off switch.
- Replace a damaged tube. If one tube still flickers in a fixture that's wired correctly, swap in a new one from our replacement parts.
Safety first: when to call an electrician
Checking seating and looking at sockets is simple, but bypassing a ballast, replacing sockets, and rewiring a fixture are line-voltage work. Always turn the power off at the breaker and confirm it's off with a voltage tester before you touch any wires. If you see burn marks or melted sockets, or if you're unsure at any step, hire a licensed electrician. Our guide Do I need an electrician to install an LED retrofit kit? can help you decide.
Orilis tip: Replacing worn sockets often cures flicker that comes and goes. If you're opening the fixture anyway, it's a good time to bypass the ballast too.
Ready to fix the flicker?
Shop double-ended LED T8 tubes, the 4-light retrofit kit, or vapor tight fixtures at orilis.com. Questions about your fixture? Email info@orilis.com or call 1-407-900-9745.